• ZZYVP nitrogen packaging device is mainly used for constant nitrogen pressure control at the top of storage tank to protect materials from nitriding and safe nitrogen packaging device of storage tank consists of ZZDQ fast relief valve and ZZV micro-pressure regulating valve. The quick relief valve is composed of a pressure controller and a ZMQ-16K single-seat shutoff valve. When the pressure in the tank rises to the set pressure, the quick relief valve opens quickly and releases the excess pressure in the tank. When the pressure in the tank decreases, the micro-pressure regulating valve opens the valve and fills the tank with nitrogen. Because the micro-pressure regulating valve must be used under the pressure of 0.1 Mpa, and the field pressure is high, ZZYP type pressure regulating valve must be installed to reduce the pressure of the pressure regulating valve to less than 0.1 Mpa before it can be used. The nominal pressure is 0.1 Mpa, and the pressure can be set in stages from 0.5 Kpa to less than 66 Kpa. The temperature of the medium is less than 80 C.

    Characteristic

    1. The nitrogen supply (discharge) pressure of the nitrogen packaging device is easy to set and can be carried out under the condition of continuous production.

    2. The setting range of nitrogen pressure is wide, as low as 0.5 Kpa (50mm.w.c) and as high as Kpa, the ratio is 132 times. The effective area of pressure detection diaphragm is large, the setting spring stiffness is small, and the action is very sensitive.

    3. Adjustment:

    (1) Nitrogen supply pressure adjustment: select a set value such as 1Kpa (100mm. w. c) within the pressure regulation range of ZZV micro-pressure regulating valve, and change the pre-compression (stretching) amount of spring 3 by adjusting the adjustment screw 2;

    (2) Nitrogen release pressure adjustment: In the pressure controller part of ZZDQ quick release valve, the pre-compression of spring 4 is changed by adjusting seat 3. Generally, in order to avoid frequent opening and closing of nitrogen packages, the nitrogen release setting value should be far away from the nitrogen supply pressure value, such as 2Kpa (200mm. w. c).

    (3) Respiratory valve high setting value adjustment: After adjusting the above two setting values, in order to avoid frequent opening and closing of the breathing valve, the setting value of the breathing valve should be greater than the setting value of pressure relief.

    Parts Materials

    Part Name

    Material Science

    valve body

    ZG230-450 ZG1Cr18 Ni9Ti

    Stem, spool, seat

    1Cr18 Ni9Ti

    diaphragm

    NBR Clamp Reinforced Tape Fabric

    Spring

    60Si2Mn

    corrugated pipe

    1Cr18 Ni9Ti

    Introduction of Outer Size of Main Technical Parameters

    Nominal pathDN

    20

    25

    32

    40

    50

    65

    80

    100

    A

    192

    232

    308

    H

    629

    631

    652

    666

    689

    797

    837

    1050

    L

    150

    160

    180

    200

    230

    290

    310

    350

    G(Kg)

    18

    19

    21

    23

    25

    37

    50

    59

    Flange specification             Company:mm

    Nominal pathDN

    20

    25

    32

    40

    50

    65

    80

    100

    D

    105

    115

    140

    150

    165

    185

    200

    220

    D1

    75

    85

    100

    110

    125

    145

    160

    180

    B

    16

    18

    20

    22

    n-ф

    4-14

    4-18

    8-18

    f1×D2

    2×56

    3×65

    3×76

    3×84

    3×99

    3×118

    3×132

    3×156

ZZYVP Nitrogen Seal Valve

ZZYVP nitrogen packaging device is mainly used for constant nitrogen pressure control at the top of storage tank to p ...

Scan two-dimensional code to share WeChat